HELIFLO HEATERS

The Devco HELIFLO direct fired heater ranges in duty from 0.25 to 100 MMBtu/Hr. it can heat a variety of process media including gas, liquids, and multi-phase fluids. It is available in a horizontal, vertical, and down-fired configuration. The HELIFLO heater provides the following standard features and options:
larger picture

EMISSIONS

Options are available to provide the Devco HELIFLO direct-fired heater with state-of-the-art low emission combustion systems to meet today’s environmentally friendly requirements...

EFFICIENCY

  • Basic Devco HELIFLO direct-fired heaters are designed with 75-85 % net thermal efficiency (NTE) without an economizer.
  • Options to increase the NTE to 90 % are available.
INSULATION
  • Light weight ceramic fiber insulation means less shipping and loading weight
  • Resistance to mechanical and thermal shock.
  • No warm-up period required. Less cold start-up and cool-down time. Heater can immediately go to high-fire.

TURNDOWN

The standard automated forced draft burner system has a 10:1 turndown ratio. Options to increase the turndown ratio are available.

MULTI - FUEL CAPABILITY

  • Gaseous Fuel
  • Liquid Fuel ( Distillate to # 6 oil )
  • Combination gas & oil
  • Low BTU Fuel supplemented with fuel blending

INSTRUMENTATION

The basic Devco HELIFLO heater includes our standard PLC burner management system ( BMS ). Options are available to provide a customized state-of-the-art BMS to meet any specification (e.g. IRI , NFPA, BASEEFA, and ATEX) and your specific information requirements.

HEAT TRANSFER MEDIA SYSTEM

HELIFLO heaters for heat media transfer applications can be furnished with a complete circulation system including:

  • ASME Code expansion tank
  • Circulation loop with by-pass valve
  • Pump(s) with isolation valves
INSTALLATION
  • Low onsite installation cost.
  • The HELIFLO heater comes completely assembled with burner, fuel train and BMS .
  • Reassembly at site involves only nuts, bolts, and gaskets. NO onsite welding or special tools are required.

 